Abstract

This study evaluates the impact of sensor type on the percentage error in an STM32-based parking sensor system by comparing the HY-SRF05 and JSN-SR04T ultrasonic sensors. The aim of this research is to determine the accuracy of each sensor in distance measurement and identify the more reliable sensor for parking sensor applications. The methodology includes installing both sensors on the STM32 system, measuring distances at various intervals, and analyzing the percentage error. The results indicate that the HY-SRF05 sensor exhibits a lower percentage error compared to the JSN-SR04T across all tested distances, from 50 cm to 300 cm. The average percentage error for the HY-SRF05 is 1.78%, while for the JSN-SR04T it is 2.6%. The conclusion of this research is that the HY-SRF05 sensor is more accurate and reliable than the JSN-SR04T for STM32-based parking sensor applications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.