Abstract
Background and Aim:Recent studies have shown that low-intensity laser therapy (LILT) enhances chronic wound healing, reduces pain, reduces inflammation, and improves post-operative rehabilitation. However, clinical outcomes in the veterinary use of LILT vary between different experimental studies. This is explained by improper laser parameter settings and limits of its penetration depth. This study aimed to investigate the penetration depth of 830 nm LILT on living dog tissue in different operating modes. This entailed continuous wave (CW) versus pulse wave (PW) and with contact versus non-contact techniques of the laser probe at different tissue-laser probe distances. The results can be applied for use in clinical practice.Materials and Methods:Twenty-four dogs that had undergone abdominal surgery were included in this study. The laser parameters were set at 200 mW, fluence of 4 J/cm2 and the laser power output denoted as mean output power (MOP) was measured by a power meter.Results:The MOP of the 830 nm CW laser was significantly higher than the PW laser (p<0.05). The MOP of the contact technique was significantly greater than that of the non-contact technique in both CW and PW modes (p<0.05). The MOP through the skin tissue was between 16.09 and 18.60 mW (8.05-9.30%) for the contact technique and 8.73 and 19.36 mW (4.37-9.68%) for the non-contact technique. In the muscle-skin layer, the MOP was between 0.50 and 1.56 mW (0.25-0.78%) and the MOP was not detected using the non-contact technique with a 5 cm tissue-laser probe distance.Conclusion:Our study indicates that 830 nm LILT (with laser parameter setting at 200 mW, fluence of 4 J/cm2 for both contact and non-contact techniques, and tissue-laser probe distance up to 5 cm) was appropriate for treatments within 14 mm of depth. However, the use of 830 nm LILT for an application in which the target tissue is deeper than 14 mm may limit its positive effect.
Highlights
Low-intensity laser therapy (LILT), known as photobiomodulation therapy, stimulates the mitochondrial respiratory chain and causes changes in cellular adenosine triphosphate or cyclic adenosine monophosphate levels [1]
The mean output power (MOP) of the 830 nm continuous wave (CW) laser was significantly higher than the pulse wave (PW) laser (p
Our study indicates that 830 nm low-intensity laser therapy (LILT) was appropriate for treatments within 14 mm of depth
Summary
Low-intensity laser therapy (LILT), known as photobiomodulation therapy, stimulates the mitochondrial respiratory chain and causes changes in cellular adenosine triphosphate or cyclic adenosine monophosphate levels [1]. A recent study indicated that NSAIDs could affect the wound healing process by reducing tissue integrity [9]. Recent studies have shown that low-intensity laser therapy (LILT) enhances chronic wound healing, reduces pain, reduces inflammation, and improves post-operative rehabilitation. Clinical outcomes in the veterinary use of LILT vary between different experimental studies This is explained by improper laser parameter settings and limits of its penetration depth. This study aimed to investigate the penetration depth of 830 nm LILT on living dog tissue in different operating modes. The results can be applied for use in clinical practice
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.