Abstract

The used of Gentamicin is still regarded for overcoming infectious diseases. Several preparations of the gentamicin are available in the market as injection, eye or ear drops, and topical dosage forms. Based on the standard method, determination of the gentamicin is carried out by microbiological assay. Several instrumental method have been reported. In this research, Thin Layer Chromatography-Densitometry (TLC-Densitometry) has been validated and used for determining gentamicin in cream dosage form. The TLC was carried out on a Silica gel GF254 using KH2PO4 20% and ninhidrin 2% solution (in ethanol 96%) as eluent and spots visualization respectively. Three spots appeared on the chromatogram having Rf value 0.51, 0.47, and 0.36. All the spots gave maximum absorption at 400 nm. The spot with Rf value of 0.51 was the highest intensity. Limit of Detection (LoD) and Limit of quantitation (LoQ) of the major component was 0.019 and 0.064 respectively. The other validation characteristics met the requirement for determination of gentamicin in the cream dosage form.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.