Abstract
In this paper, a new technology for a tangential firing pulverized coal boiler, high efficiency and low NOx combustion technology with multiple air-staged and a large-angle counter flow fuel-rich jet (ACCT for short) is proposed. To verify the characteristics of this technology, experiments of two combustion technologies, ACCT and CFS-1 (Concentric Firing System-1), are carried out under a cold model of a 1025 t/h tangential firing boiler with a PDA (particle dynamics anemometer). The distributions of velocity, particle concentration, particle diameters and the particle volume flux of primary air and secondary air are obtained. The results show that the fuel-rich primary air of ACCT can go deeper into the furnace and mix with the main flow better, which means that the counter flow of fuel-rich jets in ACCT can realize stable combustion, low NOx emission and slagging prevention.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.