Abstract

We investigated the effect of Pd concentration in Pd-doped Ag wires on the humidity reliability and interfacial corrosion characteristics between Ag wire and Al metallization. Additionally, we confirmed no corrosion problem between Ag wire and noble metal (Pd, Au) metallization, even after a pressure cooker test (PCT). The chemical composition of the tested Ag wires was pure Ag, Ag-1wt% Pd and Ag-3wt% Pd. These wires were bonded to Al and noble metal (Au, Pd) metallization using a thermo-sonic bonder. The interfaces were characterized by focused ion beam (FIB), high resolution transmission electron microscope (HRTEM) and energy dispersive X-ray spectroscopy (EDS). The interface corrosion of Pd doped Ag wires was significantly reduced as the Pd concentration in the Ag wires increased. Furthermore, the Ag wires on the noble metal (Au, Pd) metallization exhibited stable reliability during the PCT.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.