Abstract

Cigarette smoking is a source of radiation exposure due to the concentrations of natural radionuclides in the tobacco leaves. From the health point of view, measurement of (210)Pb and (210)Po contents in cigarette tobacco is important to assess the radiological effects associated with the tobacco smoking for the smokers. In the present study, activity concentrations of (210)Pb, which is a (210)Po precursor in the (238)U-decay series, were measured in cigarette tobaccos. Samples of nine different commonly sold brands of cigarette tobaccos were analysed by employing a planar high purity germanium (HPGe) low background detector. Activity concentrations of (210)Pb were measured from its gamma peak at 47 keV. Mean activity concentration of (210)Pb was measured to be 13 +/- 4 Bq kg(-1) from all samples analysed. The annual committed effective dose for a smoker and the collective committed effective dose corresponding to annual cigarettes production were estimated to be 64 +/- 20 microSv and 0.6 x 10(2) man-Sv, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.