Abstract

The Water Cooled Lithium Lead (WCLL) blanket is based on the eutectic liquid alloy Pb16Li as breeder material and neutron multiplier, and pressurised water as coolant. The liquid breeder flows at few mm/s in the blanket module while the pressurised water is circulated inside double-wall tubes.In spite of the adoption of double-wall tubes for the coolant, the probability of a water large leak because of a tube rupture accident cannot be considered negligible. As a consequence, the Pb16Li/water interaction due to a large break in one or more cooling tubes still remains one of the biggest concerns for this blanket concept.This paper reports the results of three experimental tests on Pb16Li/water interaction carried out at ENEA-Brasimone operating the LIFUS 5 facility. Water was injected into the reaction tank, containing Pb16Li at 330°C, at a pressure of 155bar with different values of sub-cooling and with different free volumes in the reaction system. In addition, post test analyses with SIMMER III code are presented in order to compare the pressure evolution measured during the experiments with that calculated by the code.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.