Abstract

A patient with long QT syndrome and syncope underwent electrophysiological testing and recording of monophasic action potentials (MAP). Programmed ventricular stimulation using up to three premature stimuli did not provoke arrhythmias. Transient action potential prolongation and afterdepolarizations were observed during pauses directly after high-rate fix frequent right ventricular burst pacing at 120-160 bpm. During the pause after burst pacing at 180 bpm, afterdepolarizations at 16-19% amplitude of the MAP plateau persisted for several beats and preceded a short episode of torsades de pointes. High-rate burst pacing provoked afterdepolarizations and triggered torsades de pointes in this patient with long QT syndrome.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.