Abstract
Personalized blood flow models are used for optimization of the Fontan procedure. In this paper we discuss clinical data for model initialization. Before the Fontan procedure patients undergo CT or MRI examination. Computational domain of interest is reconstructed from this data. CT images are shown to have a better spatial resolution and quality and are more suitable for segmentation. MRI data gives information about blood flow rates and it is utilized for setting boundary conditions in local 3D hemodynamic models. We discovered that the MRI data is contradictory and too inaccurate for setting boundary conditions: the error of measured velocities is comparable with blood velocities in veins. We discuss a multiscale 1D3D circulation model as potentially suitable for prediction of the Fontan procedure results. Such model may be initialized with more reliable data (MR measurements of blood flow in aorta and ultrasound examination of easily accessible vessels) and take into account collateral and fenestration blood flows which are typical for Fontan patients. We have calculated these flow rates for several patients and demonstrated that such flows occur systematically.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.