Abstract

Recent advancements in simulation permit patient-specific rehearsal of carotid artery stenting procedures. This study evaluates the feasibility of transferring patient-specific CT data into the simulator, creating a 3D reconstruction and performing a rehearsal. The face validity of the model was assessed. By thematic analysis of qualitative data, an algorithm was generated, focusing on simulation set-up, time of data transfer, software/compatibility issues and problem-solving strategies. The face validity of the simulated case was evaluated by 15 expert interventionalists: realism (median 4/5), training potential (median 4/5) and pre-procedure rehearsal potential for challenging CAS cases (median 4/5) were rated highly. Setting up a procedure rehearsal is feasible and reproducible for different patients in different hospital settings without major software compatibility issues. The time to create a 3D reconstruction of patient-specific CT data is a major factor in the total time necessary to set up a rehearsal. The face validity is highly rated by experts.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.