Abstract

Studies have shown that oral oxycontin tablets can be used for opioid titration. The European Society for Medical Oncology (ESMO) guidelines for adult cancer pain recommend opioid titration through the parenteral route, usually the intravenous or subcutaneous route. Patient-controlled subcutaneous analgesia (PCSA) with hydromorphone needs further evaluation for opioid titration. This prospective multicenter study was designed to compare the efficacy and safety of hydromorphone PCSA with oral oxycontin tablets for opioid titration of cancer pain. Eligible patients with cancer pain were randomly assigned in a 1:1 ratio to the PCSA group or the oxycontin group for dose titration. Different titration methods were given in both groups depending on whether the patient had an opioid tolerance. The primary endpoint of this study was time to successful titration (TST). A total of 256 patients completed this study. The PCSA group had a significantly lower TST compared with the oxycontin group (median [95% confidence interval (CI)], 5.5[95% CI:2.5-11.5] hours vs.16.0 [95% CI:11.5-22.5] hours; p<0.001). The frequency (median; interquartile) of breakthrough pain (Btp) over 24 hours was significantly lower in the PCSA group (2.5;2.0-3.5) than in the oxycontin group.(3.0; 2.5-4.5) (p=0.04). The pain was evaluated by numeric rating scale (NRS) score at 12 hours after the start of titration. The pain score (median; interquartile) was significantly lower in the PCSA versus the oxycontin group (2.5;1.5-3.0) vs 4.5;3.0-6.0) (p=0.02). The equivalent dose of oral morphine (EDOM) for a successful titration was similar in both groups (p=0.29), but there was a significant improvement in quality of life (QoL) in both groups (p=0.03). No between-group difference in the incidence of opioid-related adverse effects was observed (p=0.32). Compared with oral oxycontin tablet, the use of PCSA with hydromorphone achieved a shorter titration duration for patients with cancer pain (p<0.001), without significantly increasing adverse events (p=0.32).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.