Abstract

Prosthesis-patient mismatch (PPM) is frequent following surgical aortic valve replacement (SAVR) and is associated with an increased risk of morbidity and mortality. Preventive strategies to avoid or minimise PPM should be implemented in patients who are at high risk (i.e., patients with a small aortic annulus or those undergoing a valve-in-valve procedure within a small surgical bioprosthesis) and/or vulnerable to PPM (i.e., depressed left ventricular [LV] systolic function, severe LV hypertrophy, concomitant mitral regurgitation, and paradoxical low-flow, low-gradient aortic stenosis). Recent studies suggest that transcatheter aortic valve replacement (TAVR) may be superior to SAVR for the prevention of PPM and associated adverse cardiac events, particularly in the subset of patients with a small (<21 mm) aortic annulus. However, further randomised studies are needed to confirm the potential superiority of TAVR for this purpose.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.