Abstract

Internal fixation of patella fractures remains technically challenging. Cannulated screws with an anterior tension band have been associated with high rates of implant prominence, and fracture comminution can make appropriate application of a tension band impractical. We present the results of a novel technique using a transtendinous/transligamentous mini-fragment plate positioned peripherally around the patella with radially directed screws: termed the wagon-wheel (WW) construct. Compared with a cohort of fractures treated with cannulated screws with an anterior tension band, there was no difference in final range of motion and rate of nonunion. The WW construct had a significantly decreased incidence of symptomatic implants (5% vs. 32%, P = 0.02), rate of reoperation (9% vs. 38%, P = 0.018), dependency on gait aids (10% vs. 38%, P = 0.031), and a faster time to union (HR: 2.2; 95% CI, 1.28-3.95, P = 0.005). In summary, the WW was designed with the goal of obtaining peripheral plate fixation to maximize fragment-specific fixation while minimizing implant prominence. Patients treated with the WW demonstrated reduced rates of implant prominence and reoperation.