Abstract
Thiuram mix is tested in the standard series at a test concentration of 1% pet. The single thiurams (DPTD, TMTD, TMTM, TETD), however, are usually tested at 0.25% pet. in Germany. In other countries, the individual components of thiuram mix are tested at 1% pet. The German Contact Dermatitis Research Group (DKG) compared both patch test concentrations in 530 patients in order to find out if (i) a significant number of positive patch tests are missed by testing at the lower concentration, (ii) problems with irritant test reactions occur by increasing the test concentration to 1%, and (iii) the sensitivity of the thiuram mix rises when the breakdown test is done with the higher concentration. Slightly more positive reactions were seen with the higher concentration, but this increase did not reach statistical significance. The reaction index, as a measure for the relation of positive to irritant and/or questionable reactions, remained unchanged for the individual thiurams. The sensitivity of the mix also did not change when the breakdown test was performed with 1% pet. instead of 0.25% pet. Thus, we conclude that both concentrations are of equal diagnostic value in patch testing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.