Abstract
Grid-side current control based on capacitor-current-feedback (CCF) active damping is a common control method for <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">LCL</i> -type grid-tied inverters. The control system should not only ensure inverter stability under complex grid conditions, but also be simple in structure. Therefore, the multi-objective design for the CCF control is proposed to enhance the passivity, while improving the internal stability. Firstly, the passive constraint of CCF control is derived, from which two general control schemes, namely, negative CCF-based phase-lead (N-Lead) control scheme and positive CCF-based phase-lag (P-Lag) control scheme, are proposed. Then, the two schemes are implemented by the design of a first-order phase-lead CCF controller and a first-order phase-lag compensator-based positive CCF controller. Besides, the parameters design is also given for the convenience of engineering application. Finally, the experimental results verify the theoretical analysis and the effectiveness of the proposed design methods.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.