Application of passive samplers is demonstrated for assessment of temporal and spatial trends of dissolved polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and priority metals in the middle stretch of the Danube river. Free dissolved concentrations of PAHs, measured using SPMD samplers, ranged from 5 to 72 ng L−1. Dissolved PCBs in water were very low and they ranged from 5 to 16 pg L−1. Concentration of mercury, cadmium, lead and nickel, measured using DGT samplers, were relatively constant along the monitored Danube stretch and in the range <0.1, <1–20, 18–74, and 173–544 ng L−1, respectively. Concentrations of PAHs decreased with increasing temperature, which reflects the seasonality in emissions to water. This has an implication for the design of future monitoring programs aimed at assessment of long term trends. For such analysis time series should be constructed of data from samples collected always in the same season of the year.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.