Abstract

To assess whether implant-retained prostheses produced with a laser-sintering technique present accuracy and passive fit comparable to their milled counterparts. Two Regular Neck Straumann analogs were placed in a block of polymethyl methacrylate (PMMA) at 15 mm of distance and parallel to one another. The PMMA block was then scanned, and two groups of cobalt-chromium (Co-Cr) screw-retained, three-unit implant prostheses were fabricated using milling (control) and laser sintering (test) techniques. The prostheses were then screwed on the PMMA block, and the vertical marginal gap between the prostheses and the analogs at the implant-abutment junction was measured twice: (1) when only one screw was tightened, and (2) when both screws were fully tightened. The mean marginal gap measurements were compared to assess the difference in terms of passive fit between the laser-sintered and milled prostheses. The mean marginal gap of the milled and laser-sintered groups was 23.18 μ (SD = 6.2) and 23.71 μ (SD = 19.5), respectively. Laser-sintered prostheses presented a marginal fit comparable to milled.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.