Abstract

Localized corrosion of high level nuclear waste containers is considered an important factor that will have a strong influence on the overall performance of the proposed repository at Yucca Mountain, NV. The present candidate container material, Alloy 22 [UNS N06022 (57Ni-22Cr-13.5Mo-3W-3Fe)], is highly resistant to localized corrosion. Assessing the performance of the HLW containers also requires an evaluation of localized corrosion resistance and determination of the passive corrosion rate of Alloy 22 weldments. The localized corrosion resistance of welded Alloy 22 specimens was evaluated by measuring the repassivation potential in chloride containing solutions whereas potentiostatic tests were used to determine the passive corrosion rate of the welded material. The results for the welded material are compared to those for the base metal.