Abstract

ABSTRACTThis paper describes research in areas where the occasional failure to meet the EC standard for lead in drinking water is due to the presence of particulate lead. A method is described to disinguish between soluble, particulate and colloidal lead in tap water, and characteristics are given of water sources which are most likely to suffer from this form of lead problem. At least two types of particulate (insoluble) lead in tap water have been identified, and some factors are discussed which cause the occurrence of both types. Interim results of trials are presented, with remedial actions.