Abstract
The particle size distribution of the shielded metal arc welding fumes is studied. The laser aerosol spectrometer and optoelectronic aerosol counter with the total measurement range of 0.15–10 μm were used. It is demonstrated that the number-based size distribution is described by the three-modal lognormal distribution, where the first two modes are the result of the liquid-phase and solid-phase coagulation and the third mode is the coarse fume particles. The linear dependency of the average size of the particles on the product of welding parameters: the arc resistance, the wire feed rate and the electrode sectional area is revealed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.