Abstract
The mass size distribution of beryllium aerosols generated in the various operational areas of a typical extraction and processing plant was studied using an eight-stage impactor sampler. The total concentration of beryllium in the plant was found to be well below the threshold limit value. The mean value of mass median aerodynamic diameter of beryllium particles observed for various operations ranged from 5.0–9.5 µm. The alveolar deposition for various operational areas was estimated to be 3–5% for nasal breathing and 9–13% for oral breathing based on the International Commission on Radiological Protection (ICRP) human respiratory tract model. Deposition during oral breathing was higher than during nasal breathing by approximately a factor of two to three. This study on exposure characterization was useful for reducing the respirable fraction of beryllium aerosol by optimizing the capture velocity and improving the quality of other control measures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.