Abstract

Colloidal particle size is an important characteristic to consider when choosing a radiopharmaceutical for diagnosis and therapeutic purposes in nuclear medicine. Photon correlation spectroscopy (PCS) and transmission electron microscopy (TEM) were used to determine the particle-size distribution of (90)Y- and (99m)Tc-labelled antimony trisulfide (Sb(2)S(3)) and tin colloids (Sn-colloid). (90)Y-Sb(2)S(3) and (99m)Tc-Sb(2)S(3) were found to have a diameter of 28.92 +/- 0.14 and 35.61 +/- 0.11 nm, respectively, by PCS. By TEM, (90)Y-Sb(2)S(3) particles were measured to be 14.33 +/- 0.09 nm. (90)Y-labelled Sn colloid were found to exist with a d(v(max1)) of 805 nm and a d(v(max2)) of 2590 nm, by PCS, whereas (99m)Tc-Sn colloid was shown to have more than 80% of radioactive particles of approximately 910 nm by PCS. For (90)Y-labelled Sb(2)S(3) and Sn colloid, a comparison of TEM and PCS indicates that these techniques found significantly different mean diameters. TEM has an excellent resolution necessary for radiocolloid particle-sizing analysis, and it is a desirable size-measuring technique because it is more reliable than PCS.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.