Abstract

Particle emission rates measured from ultra-high purity, cleanroom gas handling components following the test procedures specified in the SEMATECH test methods are described. A condensation nucleus particle counter (CNC) having a counting efficiency of 50 percent at 0.02 μm in diameter was used to measure the total particle contribution from the gas handling components. A spool piece was inserted to measure the baseline particle concentration of the test stand before the measurement of the test component was carried out. Eighteen test samples, six each from three suppliers (two domestic and one foreign), in each type of gas handling components (valves, point-of-use filters, pressure regulators), were tested using the revised test method. Particle contribution data obtained for fresh out-of-the-bag, stainless steel (SS) test samples, 1/4-in. in OD, from different manufacturers are summarized in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.