Abstract

The present research focuses on the efficiency improvement at part-load of a centrifugal fan for a 30 kW fuel cell combined heat and power (CHP) unit. For this purpose, the fan stage is equipped with a partially vaned diffuser with a variable cross-sectional area using a moving backplate. The design and the performance of the partially vaned diffuser with a variable cross-sectional area are described in the first part of this paper. The performance results are compared to measurements of the same centrifugal fan with a vaneless diffuser carried out for the previous investigation. For the second part, the influence of the variable cross-sectional area on the diffuser flow field is investigated using optical PIV (Particle Image Velocimetry) measurements and CFD (Computational Fluid Dynamics) simulations. The combination of a variable cross-section, partially vaned diffuser was able to achieve a 10 percent increase in pressure ratio, a 5 percentage points increase in part-load efficiency while maintaining the whole operating range of the vaneless, constant cross section reference design.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.