Abstract

Abstract The effects of partial premixing on a reacting jet-in-crossflow is investigated in a five atmosphere axially staged combustor at stationary gas turbine relevant conditions. The facility consists of a dump style headend burner that provides a crossflow with a quasi-uniform velocity and temperature profile to the axial stage to isolate the effects of the jet-in-crossflow. The headend burner is run with methane and air at a lean equivalence ratio to match industry emission standards. For this work, the total air to the headend and axial stage is kept constant, and fuel is split between the headend and axial stage to represent different gas turbine loading conditions. For the cases analyzed, the fuel split to the axial stage went up to 25%. The axial stage consists of an optically accessible test section with a coaxial injector that provides variability to how long the methane and air can mix before entering the facility. Three different premixed levels are studied: fully premixed, nonpremixed, and partially premixed. The flow-field characteristics of the reacting jet-in-crossflow are analyzed using particle image velocimetry (PIV), and flame behavior is quantified by employing CH* chemiluminescence. NO measurements are made at the exit of the facility using a Horiba emissions analyzer. Two different flames are observed: flames that burn in the leeward recirculation region and flames that burn at the core of the jet.