Abstract

Partial discharge measurement and subsequent analyses is one of important and capable test of electro-technological diagnostics. This test evaluates the properties of electrical insulation system of electrical machines and devices. There are a lot of partial discharge test methods based on physical or chemical detection of partial discharge. Described experiment consists of laboratory testing of partial discharges activity of insulating material samples in different insulating fluids. Flat specimens of insulation were prepared, aged and the partial discharges were measured accordingly. The trends of partial discharge main parameters (ignition voltage, extinguish voltage, pulse count, average discharge current, peak charge level) are studied and described in dependence on exposure time, temperature and applied voltage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.