Abstract

This work investigates the partial discharge (PD) characteristics of twisted pair samples for inverter-fed motor coil under ac and surge voltage conditions. It also discusses the difference in the PD inception characteristics of a twisted pair under 60-Hz voltage and surge voltages with a steep wave front. The PDIV under ac voltage was measured and was found to agree well with the theoretical value using electric field analysis and Paschen's law. The PDIV under surge voltage was measured for different repetition rates and the PDIV for 60-pps repetition was found to be lower than those for 6 pps and for the single shot, which suggested that the electrical insulation performance would be influenced by the repetition rate. The PDIV under surge voltages was 1.5 to 1.8 and 2.3 to 2.7 times higher than those under AC voltage application for the used and virgin samples, respectively.