Abstract

shaped internal corrosion defects. Measurements were taken in order to determine the actual dimensions of each of the tubular specimens and their respective metal loss defect profiles. Tensile specimens were tested to determine the actual material properties. The failure pressures measured in the laboratory tests were compared with those predicted by four assessment methods: the ASME B31G method, 4 the DNV RPF101 method for single defects, 5 the RSTRENG effective area method, 7 and the DNV RP-F101 method for complex-shaped defects. 5