Abstract

The parastomal hernia is a continuing challenge, because of the disappointing results of the different procedures available to repair it. The mesh implantation seems to be the best, but not optimal method with 8-22 % recurrence rate and about 15-20% other complications. The PHSL (Polypropylene hernia system large; Ethicon inc. Johnson and Johnson, USA) device proved to be an acceptable solution in correction the medium and large parastomal hernia with low recurrence and complication rate. The device enforces the abdominal wall with double mesh layer connected with a tube. The sigmoid colostomy is lifted trough the tube to the abdominal surface. The device was implanted with preventive intent in 14 cases, without any parastomal hernia formation in the first postoperative year. The preventive PHSL mesh implantation at the Miles operation seems to be an useful method for prevention of parastomal hernias.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.