Abstract
In the measurement of transparent planar element using deflectometry, the fringe patterns reflected off the double surfaces of transparent planar element are superimposed on the camera, causing the phenomenon of parasitic reflection. The parasitic reflection makes it difficult for traditional deflectometry to accurately obtain the front surface shape. Previous solutions suffer from inability to reliably measure the element with thickness less than 10 mm. In practice, modulated by the nonlinear response, the signal captured by the camera contains higher-order harmonics, whose frequency difference is larger than that of the fundamental. Therefore, a novel method based on harmonic analysis is proposed. This parasitic issue of thin transparent element can be eliminated by analyzing the harmonic component in power spectrum. The surface shape of element with thickness of 5 mm is measured in experiment. The measurement error is around 80 nm in RMS with a diameter of 52 mm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.