Abstract

Thermal performance criterion of the TACB (Test Auxiliary Cold Box) dictates the need for an effective thermal shield between the ambient temperature at 300 K and the cold mass at 4 K, in line with the maximum heat load limitation of the cryoplant at 4 K temperature level. This thermal shield, to be forced flow cooled and maintained at 80 K temperature level will screen direct thermal conduction and radiation heat loads from the ambient to the cold mass. The design objective is to attain cool-down of the shield within a desired time frame with least possible cryogen mass flow rate and pressure drop across the thermalization channel while adhering to the allowable heat load limit at 80 K temperature level. In the present paper, a transient thermal analysis is carried out by varying the process conditions, i.e. pressure and mass flow rate of the cooling fluid to compare time dependent thermal characteristics of the shield during cool-down and decide the optimum flow parameters from the available range.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.