Abstract

The force identification can be mathematically viewed as the mapping from the observed responses to external forces through a matrix filled with system Markov parameters, which makes it difficult or even impossible for long time duration. A potentially efficient solution is to sequentially perform the identification processing. This paper presents a parametric study on the sequential deconvolution input reconstruction (SDR) method, which was proposed by Bernal. The behavior of the SDR method due to the effects of window parameters, noise levels and sensor configurations is investigated. In addition, a new normalized standard deviation of the reconstruction error over time is derived to cover the effect of only independent noise entries. The sinusoidal and band-limited white noise excitations are tested to be identified with good accuracy even with 10% noise. The simulation results yield various conclusions that may be helpful to engineering practitioners.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.