The containment liner should maintain its structural integrity and thus its leak-tightness under any accidental condition. The liner is not used as a structural member to resist any mechanical loads; however, pressure, shrinkage of the concrete, and temperature changes will induce strains in the liner and the anchorage system. In this paper, a parametric study of the behavior of the liner strains and anchor forces and displacements caused by a temperature rise due to loss of coolant accident (LOCA) has been conducted. The following variations were considered in the study: (1) ½-in. (6-mm) versus ⅜-in. (10-mm) liner thickness; (2) stud anchors versus spacings; (3) vertical and horizontal spacings; and (4) ⅝-in. (16-mm) versus ¾-in. (19-mm) diam. studs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.