Abstract
SummaryPassive energy dissipation devices have been used around the world to mitigate the response of structures under dynamic excitations, such as wind or seismic loading. The use of tuned mass dampers (TMD) in tall and slender buildings to reduce unwanted responses has proved to be very effective. The main purpose of this work is to study the structural behavior of a 115‐m‐height slender monument fitted with TMDs subjected to simulated wind and seismic loading. Turbulent wind forces were calculated based on samples of turbulent wind speed simulated with an auto regressive and moving average (ARMA) model. Ground motions compatible with a seismic site spectrum were also simulated. An optimization approach is suggested to determine the parameters of the TMDs that reduce the structural response to the maximum. The effectiveness of the TMDs for reducing the structural response of the monument is discussed in detail, and the use of optimally tuned TMDs is emphasized.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Structural Design of Tall and Special Buildings
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.