Abstract

This work explains the design of notched cantilever beam for energy harvesting through parametric study. Conventional cantilever beam with proof mass is compared with half-sine arc-shape notched cantilever beam. The effect of the position, length, and depth of the arc on the performance of the device is studied. Maximum stress, beam bending, frequency, electric output power and surface charge of the two designs are compared. For the designed cantilever beam, results show 9.2% decrease in maximum stress, which translates to about 47.72% increase in harvested power with a slight decrease (2.12 %) in resonant frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.