Abstract
The use of heat pipes in solar collectors offers several advantages regarding flexibility in operation and application, as they are very efficient in transporting heat even under a small temperature difference. Compared with other systems powered by evacuated tube collectors or flat plate solar collectors using a wickless heat pipe, little attention has been paid to a flat plate solar collectors wick assisted heat pipe. In this paper an analytical model based on energy balance equations assuming a steady state condition was developed to evaluate the thermal efficiency of a flat plate wick assisted heat pipe solar collector. Parameters which affect the collector efficiency are identified, such as tube spacing distance, gap spacing between the absorber plate and the glazing cover, and the emissivity of the absorber plate. The results reflect the contribution and significance of each of these parameters to the collector overall heat loss coefficients. Three heat pipe working fluids are examined and results show that acetone performs better than methanol and ethanol.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.