Abstract

Optimal design of a piping system connected in the multi‐stage turbo blower has been performed using response surface method and three‐dimensional Navier‐Stokes analysis to reduce pressure loss in the piping system. To analyze three‐dimensional flow field in the piping system including a multi‐stage turbo blower, general analysis code, CFX, is employed in the present work. SST turbulence model is employed to estimate the eddy viscosity. Unstructured grids are used to represent a composite grid system including circular duct, blower impeller, casing and gate valve. Throughout the optimization of a piping system using two design variables defined the radius of an inlet and outlet ducts, the pressure loss in the piping system is successfully reduced by decreasing local losses in the piping system. Detailed flow analysis is performed using the reference and optimum shape of the connecting duct.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.