Abstract

The relation for the limiting temperature of water heating in a contact gas–droplet-type apparatus with a centrifugal atomizer has been determined experimentally in relation to the conditions of utilization of heat of power plant waste-gases. Investigations were carried out in the range of excess water pressures in front of the atomizer 0.2–0.6 MPa and of the volume fraction of steam in the vapor–gas mixture at the inlet of the apparatus from 0.02 to 0.45. The possibility of using the obtained dependence for calculating the limiting values of the vapor–gas flow parameters that limit the range of efficient operation of the contact apparatus with steam condensation and in the absence of heated liquid droplet evaporation is shown.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.