Abstract

Based on the method of controlling welding stress with trailing, the electromagnetic force in coil-sheet system was simulated with finite element software ANSYS. The effect of parameters of coil on the electromagnetic force density f y was analyzed. The results show that the maximum electromagnetic force density f y, max in sheet appears in the position near the inner radius of single-turn coil. The position is independent of section shape of coil. f y, max for flat coil is larger than that for long coil and the coil with wedge shape section, while section areas of all coils are equal to each other. The effect of turn number of multiple-turn coil on f y is dependent on the loop resistance in circuit. The kind of coil with more turns and larger inductance is commended while there is larger loop resistance in circuit. f y increases in a certain magnitude while a magnetic core is located in coil. However, the magnitude of f y is limited by saturating magnetic flux of the core.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call