Abstract
In this work, Scheffler dish with improved design of the receiver is used for direct steam generation. Experiments were conducted from February to May 2019, for monthly performance assessment of 16 m2 Scheffler concentrator. Effect of varying aperture area, solar beam radiation, ambient temperature and wind speed on the thermal efficiency of the system is investigated. The average receiver temperature at focus observed to be 323°C with average beam radiation 656 W/m2. From the results, the thermal efficiency of the system is reduced by 2.36% with a decrease in aperture area from 12.82 m2 to 9.59 m2. The average thermal efficiency of the system decreased linearly from 57.29% to 39.99% with an increase in wind speed from 0.5 m/s to 6 m/s where as it reduced by 1.13% with an increase in ambient temperature from 24°C to 46°C.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Renewable Energy Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.