Abstract
The goal of this study is to investigate the effect of key design parameters on the thermal performance of the packed bed heat storage device by numerical calculation. A one-dimensional, non-equilibrium packed bed latent heat storage mathematical model was established and the applicability of the model was verified. The results demonstrate that the inlet temperature of the heat transfer fluid (HTF) had the greatest influence on each index. When the inlet temperature increased from 333 K to 363 K, exergy destruction increased threefold, effective heat storage time decreased by 67%, effective heat storage increased by 38%, and exergy efficiency decreased by 11%. The decrease of the capsule diameter had a positive effect on each evaluation index. According to the sensitivity analysis, the order of importance of each parameter within their variation range was HTF inlet temperature, HTF flow rate, PCM capsule size and PCM initial temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.