Abstract

This paper is concerned with bump-less transfer of parameterized disturbance observer based controller with individual pitch control strategy to reduce cyclic loads of wind turbine in full load operation. Cyclic loads are generated due to wind shear and tower shadow effects. Multivariable disturbance observer based linear controllers are designed with objective to reduce output power fluctuation, tower oscillation and drive-train torsion using optimal control theory. Linear parameterized controllers are designed by using a smooth scheduling mechanism between the controllers. The proposed parameterized controller with individual pitch was tested on nonlinear Fatigue, Aerodynamics, Structures, and Turbulence (FAST) code model of National Renewable Energy Laboratory (NREL)’s 5 MW wind turbine. The closed-loop system performance was assessed by comparing the simulation results of proposed controller with a fixed gain and parameterized controller with collective pitch for full load operation of wind turbine. Simulations are performed with step wind to see the behavior of the system with wind shear and tower shadow effects. Then, turbulent wind is applied to see the smooth transition of the controllers. It can be concluded from the results that the proposed parameterized control shows smooth transition from one controller to another controller. Moreover, 3p and 6p harmonics are well mitigated as compared to fixed gain DOBC and parameterized DOBC with collective pitch.

Highlights

  • This paper proposes multivariable linear parameter varying controller based on disturbance observer based control (DOBC) technique to reduce the effect of cyclic loads using individual pitch control (IPC) strategy

  • This paper presents a systematic approach to design a linear parameter varying with individual pitch control for full load operation of wind turbine with objectives to regulate output power and reduce fatigue under periodic loads

  • K0 is the controller at operating point (18 m/s, 14.92 deg) and K1 is the linear controller at operating point of (19 m/s, 16.23 deg) with rated generator torque for full load operation of wind turbine

Read more

Summary

Introduction

This paper proposes multivariable linear parameter varying controller based on disturbance observer based control (DOBC) technique to reduce the effect of cyclic loads using individual pitch control (IPC) strategy. Multivariable DAC was developed [2] to mitigate the effect of periodic loads (wind shear and tower shadow) with multiple objectives using pitch control of wind turbine. Quadratic Gaussian controller was developed to mitigate the effect of sensor noise [18], DAC with optimal control theory was designed to get better stability of output power [1] and 3p harmonics generated due to periodic loads were reduced using CPC [2,19]. This paper presents a systematic approach to design a linear parameter varying with individual pitch control for full load operation of wind turbine with objectives to regulate output power and reduce fatigue under periodic loads.

Wind Turbine Model
Control Methodology
Parameterized DOBC with CPC
Parameterized DOBC with IPC
Problem Formulation
Simulation Results
Conclusions