Abstract

Duplex Stirling coolers are external heat-driven regenerative machines that obtain cooling power with high efficiency and reliability. Although the technology is promising, little progress has been reported since they were invented. This paper examines the influence of system parameters on the cooling performance of a duplex Stirling cooler. The study showed that the system was sensitive to a number of parameters, as slight changes in these parameters resulted in the cooling performance deviating significantly from the design. In practice, deviation of system parameters from the design is inevitable. Therefore, actual systems often produce unexpected performance, and this is likely the main obstacle to utilizing such a system in practical applications. To overcome this disadvantage, two methods were proposed to allow the power piston to move with a constant displacement, which may allow for duplex Stirling coolers to become a more widely used cooling system. A new configuration for duplex Stirling coolers was also considered, and it showed similar characteristics as the typical configuration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.