Abstract

Aiming at the problems of low transmission power and low transmission efficiency in the non-contact energy transmission system, a bilateral LCC compensation network structure under zero voltage turn-on is optimized. Using the fundamental waveform analysis method and the superposition method, the static working characteristics of the system compensation topological equivalent circuit are analyzed, and the system compensation parameter design and ZVS implementation adjustment design are completed. It can work at a constant frequency and reduce switching losses and switching stresses to improve overall system efficiency. Finally, in the system simulation environment, establish a two-way inductive power transfer system for verifying the zero-voltage switching optimized compensation network reliability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.