Abstract

This paper deals with parameter fault diagnosis in heat exchange networks (HENs) with joining and splitting connections where the change in the heat transfer coefficient is considered as fault. The fault diagnosis oriented model of the HEN elements was developed based on the equivalent LTI realization of distributed delay models. The Signed Directed Graph (SDG) method is used to derive the fault observability conditions. The presence of faults induces bilinear fault-input terms into the system model. Thus, a nonlinear adaptive observer was proposed for fault diagnosis. To verify and validate the proposed method, a case study is presented. The simulation results show that the observers are successfully detecting and estimating the faults and unknown system states.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.