Abstract

Two typical types of small-scale natural gas liquefaction process in skid-mounted package were designed and simulated. The key parameters of the two processes were compared, and the matching of the heating and cooling curves in heat exchangers was also analyzed. The results show that the N 2–CH 4 expander cycle precedes the mixed-refrigerant cycle on the premise of lacking propane pre-cooling. Large temperature difference and heat exchange load are the primary reasons of exergy loss in heat exchangers. The power consumption of compressors is influential to power consumption per unit LNG, so compression with intercooling should be adopted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.