An adiabatic demagnetization refrigerator (ADR) is described which was designed for use in the multiband imaging photometer for the Space Infrared Telescope Facility (SIRTF). This refrigerator was required to cool bolometric detectors for infrared and millimetre waves to 0.1 K. A paramagnetic salt pill with a number of novel features was developed to meet the stringent requirements for an ADR used in space. An unusual paramagnetic salt, chromic caesium alum (CCA), is used to meet the requirement of thermal stability under the bake-out temperatures used in commissioning space cryogenic vacuum systems. The cycle time for the refrigerator has been reduced to ≈30 min by attention to thermal time constants and by growing the CCA salt directly on to an array of gold wires. Crystal growing procedures were developed to overcome problems with the low solubility of CCA in water. The salt pill is sealed in stainless steel to retain water of hydration and is constructed of materials which are not corroded by commonly used paramagnetic salts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.