Abstract

This work provides a generalized theory of proton relaxation in inhomogeneous magnetic fields. Three asymptotic regimes of relaxation are identified depending on the shortest characteristic time scale. Numerical simulations illustrate that the relaxation characteristics in the regimes such as the T 1/ T 2 ratio and echo spacing dependence are determined by the time scales. The theoretical interpretation is validated for fluid relaxation in porous media in which field inhomogeneity is induced due to susceptibility contrast of fluids and paramagnetic sites on pore surfaces. From a set of measurements on model porous media, we conclude that when the sites are small enough, no dependence on echo spacing is observed with conventional low-field NMR spectrometers. Echo spacing dependence is observed when the paramagnetic materials become large enough or form a ‘shell’ around each grain such that the length scale of the region of induced magnetic gradients is large compared to the diffusion length during the time of the echo spacing. The theory can aid in interpretation of diffusion measurements in porous media as well as imaging experiments in presence of contrast agents used in MRI.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.