In this paper the behavior analysis of parallel connection of IGBTs under short circuit conditions is presented. The issues of hard switching fault (HSF) and fault under load (FUL) short circuit types are faced by taking into account for the influence of the layout and gate driving parameters. The role of the temperature has been considered too in order to investigate how this quantity affects the IGBTs short circuit phenomenon. An analytical description of the FUL transient is introduced to put in correlation the current and voltage peaks, which are suffered by the IGBT, to the circuit and device parameters. Indeed, the current peak imbalance appearing in a FUL condition is depending on the power layout, on the gate driving conditions and spread on device parameters.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.