Abstract

In this paper we introduce the idea of parallel pipelining for water lubricated transportation of oil (or other viscous material). A parallel system can have major advantages over a single pipe with respect to the cost of maintenance and continuous operation of the system, to the pressure gradients required to restart a stopped system and to the reduction and even elimination of the fouling of pipe walls in continuous operation. We show that the action of capillarity in small pipes is more favorable for restart than in large pipes. In a parallel pipeline system, we estimate the number of small pipes needed to deliver the same oil flux as in one larger pipe as N = (R/r)α, where r and R are the radii of the small and large pipes, respectively, and α = 4 or 19/7 when the lubricating water flow is laminar or turbulent.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.